Sulfide |
 |
| |
Method
References: USEPA Methods for Chemical Analysis of Water and Wastes, Method 376.2 (1983). APHA Standard Methods, 21st ed., Method 4500-S2-D (2005).
Sulfides are naturally present in ground waters as a result of leaching from sulfur-containing mineral deposits. Surface waters do not usually contain high sulfide concentrations. Sulfides result from the decomposition of organic matter, from bacterial sulfate reduction under anaerobic conditions and from various chemical processes.
CHEMetrics™ test kits measure total acid soluble sulfides and employ the methylene blue methodology. Sulfides react with dimethyl-p-phenylenediamine in the presence of ferric chloride to produce methylene blue. Results are expressed as ppm (mg/L) S.
If no shelf-life is listed for a product, then the shelf-life is at least 2 years. |
| |
| • Click to View MSDS and Kit instructions |
 |
| |
Visual Kits |
0-1 & 1-10 ppm
0.05 ppm / Method: Methylene Blue |
| |
Cat# |
| CHEMets Kit |
K-9510 |
| | CHEMets Refill, 30 ampoules | R-9510 |
| | Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years | A-9500 |
| | Low Range Comparator, Shelf-life 2 years:
0, 0.1, 0.2, 0.3, 0.4, 0.6, 0.8, 1.0 ppm | C-9501 |
| | High Range Comparator, Shelf-life 2 years:
1, 2, 3, 4, 5, 6, 7, 8, 10 ppm | C-9510 |
| | Kit comes in a plastic case and contains everything needed to perform 30 tests: Refill, Low and High Range Comparators, Activator Solution, 25 mL sample cup, instructions, and MSDS. | |
|
0-30 & 30-300 ppm
5 ppm / Method: Methylene Blue |
| |
Cat# |
| VACUettes Kit |
K-9510D |
| | VACUettes Refill, 30 ampoules | R-9510D |
| | Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years | A-9500 |
| | Low Range Comparator, Shelf-life 2 years:
0, 5, 7.5, 10, 15, 20, 25, 30 ppm | C-9501D |
| | High Range Comparator, Shelf-life 2 years:
30, 60, 90, 120, 150, 175, 200, 250, 300 ppm | C-9510D |
| | Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, Activator Solution, dilutor snapper cup, micro test tube, instructions, and MSDS. | |
|
0-60 & 60-600 ppm
10 ppm / Method: Methylene Blue |
| |
Cat# |
| VACUettes Kit |
K-9510A |
| | VACUettes Refill, 30 ampoules | R-9510A |
| | Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years | A-9500 |
| | Low Range Comparator, Shelf-life 2 years:
0, 10, 15, 20, 30, 40, 50, 60 ppm | C-9501A |
| | High Range Comparator, Shelf-life 2 years:
60, 120, 180, 240, 300, 350, 400, 500, 600 ppm | C-9510A |
| | Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, Activator Solution, dilutor snapper cup, micro test tube, instructions, and MSDS. | |
|
|
0-120 & 120-1200 ppm
20 ppm / Method: Methylene Blue |
| |
Cat# |
| VACUettes Kit |
K-9510B |
| | VACUettes Refill, 30 ampoules | R-9510B |
| | Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years | A-9500 |
| | Low Range Comparator, Shelf-life 2 years:
0, 20, 30, 40, 60, 80, 100, 120 ppm | C-9501B |
| | High Range Comparator, Shelf-life 2 years:
120, 240, 360, 480, 600, 700, 800, 1000, 1200 ppm | C-9510B |
| | Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, Activator Solution, dilutor snapper cup, micro test tube, instructions, and MSDS. | |
|
0-1200 & 1200-12,000 ppm
200 ppm / Method: Methylene Blue |
| |
Cat# |
| VACUettes Kit |
K-9510C |
| | VACUettes Refill, 30 ampoules | R-9510C |
| | Activator Solution Pack, six 10 mL bottles, Shelf-life 2 years | A-9500 |
| | Low Range Comparator, Shelf-life 2 years:
0, 200, 300, 400, 600, 800, 1000, 1200 ppm | C-9501C |
| | High Range Comparator, Shelf-life 2 years:
1200, 2400, 3600, 4800, 6000, 7000, 8000, 10,000, 12,000 ppm | C-9510C |
| | Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, Activator Solution, dilutor snapper cup, micro test tube, instructions, and MSDS. | |
|
|
|
 |
| |
Instrumental Kits |
V-2000: 0.20-3.00 ppm / Spec: 0.10-1.00 ppm
Methylene Blue |
| |
Cat# |
| Vacu-vials Kit |
K-9503 |
| | Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules, Activator Solution, 25 mL sample cup, ampoule blank, instructions, calibration table, and MSDS. | |
|
|
0.60-6.00 ppm
Methylene Blue |
| |
Cat# |
| Vacu-vials Kit |
K-9523 |
| | Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules, Activator Solution, 25 mL sample cup, ampoule blank, instructions, calibration table, and MSDS. | |
|
|
|
 |
| |
Kit Components common to Sulfide |
| Description |
Cat# |
| | Sample Cup Pack, 25 mL (6 ea) | A-0013 |
| | Micro Test Tube Pack (10 ea) | A-0015 |
| | Dilutor Snapper Cup Pack (6 ea) | A-0018 |
| | Ampoule Blank Pack (5 ea) | A-0023 |
|
|
|
|
|
| |
|