LOOK AT HERE
 
Why CHEMetrics?
Catalogue PDF
Applications
Trade Shows
Kit Instructions
Frequently Asked Questions
 
 
  SEARCH
 
Enter text to Search:


 
 
Vietnamese
 
 
Jump to Method
  Cyanide
 
Methods

Cyanide is used in many chemical and refining processes. It is found in effluent from electroplating and metal cleaning operations, coke ovens, steel manufacturing facilities, and gas scrubbers. Although cyanide can be safely removed by alkaline chlorination, its acute toxicity to aquatic life necessitates routine monitoring of effluents. The Maximum Contaminant Level for free cyanide in drinking water is 0.2 mg/L.

CHEMetrics’ cyanide test kits are applicable to the monitoring of effluents and surface water supplies. It is recommended, however, that the sample be distilled and hydrogen sulfide be removed prior to analysis.

The Isonicotinic-Barbituric Acid Method

Reference: S. Nagashima, Spectrophotometric Determination of Cyanide with Isonicotinic Acid and Barbituric Acid, International Journal of Environ. Anal. Chem., 1981, Vol. 10, pp. 99-106.

With CHEMetrics’ method based on the isonicotinic/barbituric acid procedure, chlorine is added to a sample that has been buffered to pH 6. The resulting cyanogen chloride reacts with isonicotinic and barbituric acids to form a blue color. Results are expressed as ppm (mg/L) CN.

This chemistry provides two advantages over the more commonly used pyridine methods: (1) The shelflife of the reagent is extended, and (2) the analyst is not exposed to noxious and hazardous fumes from the pyridine reagent.

The Silver Nitrate Method

Reference: APHA Standard Methods, 20th ed., pp. 4-38, Method 4500-CN- D (1998).

CHEMetrics employs silver nitrate as the titrant and 5-(p-dimethylaminobenzylindene) rhodanine as the indicator. A color change from orange to yellow signals the end of the titration. Results are expressed as ppm (mg/L) CN.
 
Click to View MSDS and Kit instructions
 
  Visual Kits
0-0.1 & 0.1-1 ppm
0.005 ppm / Method: Isonicotinic-Barbituric Acid
  Cat#
CHEMets Kit K-3810

CHEMets Refill, 30 ampoulesR-3810

Neutralizer Solution Pack, six 20 mL bottles, Shelf-life 2 yearsA-3800

Activator Solution Pack, six 10 mL bottles, Shelf-life 2 yearsA-3801

Low Range Comparator, Shelf-life 2 years: 0, 0.01, 0.02, 0.03, 0.04, 0.06, 0.08, 0.10 ppmC-3801

High Range Comparator, Shelf-life 2 years: 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 1.0 ppmC-3810

Kit comes in a plastic case and contains everything needed to perform 30 tests: Refill, Low and High Range Comparators, Neutralizer Solution, Activator Solution, 5 mL sample cup & top, instructions, and MSDS.
Click here to Buy Now Complete Kits!

5-50 ppm
5.0 ppm / Method: Silver Nitrate
  Cat#
Titrets Kit K-3815

Increments: 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 9.0, 10.0, 12.5, 15.0, 17.5, 20.0, 25.0, 35.0, 50.0 ppm

Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules with valve assemblies, Indicator Solution, titrettor, 25 mL sample cup, instructions, and MSDS.
Click here to Buy Now Complete Kits!

 
  Instrumental Kits
0.020-0.400 ppm
Isonicotinic-Barbituric Acid
  Cat#
Vacu-vials Kit K-3803

Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules, Neutralizer Solution1, Activator Solution1, 25 mL sample cup, 3.0 mL syringe, ampoule blank, instructions, calibration table, and MSDS.

Kit didatangkan di dalam kotak kadbod dan mengandungi semua keperluan untuk melakukan 30 ujian: tigapuluh ampul, Larutan1 Penutral, Larutan1 Pengaktif, cawan sampel 25mL, picagari 3.0mL, blank ampul, arahan, jadual penentukuran dan MSDS.
Click here to Buy Now Complete Kits!

 
Kit Components common to Cyanide
Description Cat#

Sample Cup Pack , 25 mL (6 ea)A-0013

Ampoule Blank Pack (5 ea)A-0023

Titrettor Pack (1 ea)A-0053

Syringe Pack, 3.0 mL (6 ea)A-0063

Sample Cup & Top Pack, 5 mL (6 ea)A-0105
Click here to Buy Now Complete Kits!
 
Tel: 02 87065400
Email: sales@watertestsystems.com.au
Watertest Systems Pty Ltd 2006