Carbon Dioxide |
 |
| |
Method
References: APHA Standard Methods, 20th ed., pp. 4-31, Method 4500-CO2 C (1998). ASTM D 513-82, Total and Dissolved Carbon Dioxide in Water, Test Method E.
Dissolved carbon dioxide (CO2) is naturally present as a result of animal respiration, the decay of organic matter, and the decomposition of certain minerals. It is the major source of acidity in unpolluted water samples. Surface waters typically contain less than 10 ppm (mg/L) dissolved CO2, while ground waters, particularly if deep, may contain several hundred ppm (mg/L).
CHEMetrics’ carbon dioxide test kits employ a sodium hydroxide titrant and phenolphthalein indicator. The kits contain a neutralizer solution to correct for sulfide interference. Results are expressed as ppm (mg/L) CO2.
If no shelf-life is listed for a product, then the shelf-life is at least 2 years. |
| |
| • Click to View MSDS and Kit instructions |
 |
| |
Visual Kits |
10-100 ppm
10 ppm / Method: Caustic Titrant with pH Indicator |
| |
Cat# |
| Titrets Kit |
K-1910 |
| | Increments:
10, 11, 12, 13, 14, 15, 16, 18, 20, 25, 30, 35, 40, 50, 70, 100 ppm | |
| | Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules with valve assemblies, Activator Solution, Neutralizer Solution, titrettor, 25 mL sample cup, 1.0 mL syringe, instructions, and MSDS. | |
|
100-1000 ppm
100 ppm / Method: Caustic Titrant with pH Indicator |
| |
Cat# |
| Titrets Kit |
K-1920 |
| | Increments:
100, 110, 120, 130, 140, 150, 160, 180, 200, 250, 300, 350, 400, 500, 700, 1000 ppm | |
| | Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules with valve assemblies, Activator Solution, Neutralizer Solution, titrettor, 25 mL sample cup, 1.0 mL syringe, instructions, and MSDS. | |
|
|
250-2500 ppm
250 ppm / Method: Caustic Titrant with pH Indicator |
| |
Cat# |
| Titrets Kit |
K-1925 |
| | Increments:
250, 275, 300, 325, 350, 375, 400, 450, 500, 625, 750, 875, 1000, 1250, 1750, 2500 ppm | |
| | Kit comes in a cardboard box and contains everything needed to perform 30 tests: thirty ampoules with valve assemblies, Activator Solution, Neutralizer Solution, titrettor, 25 mL sample cup, 1.0 mL syringe, instructions, and MSDS. | |
|
|
|
 |
| |
Kit Components common to Carbon Dioxide |
| Description |
Cat# |
| | Sample Cup Pack, 25 mL (6 ea) | A-0013 |
| | Syringe Pack, 1.0 mL (6 ea) | A-0027 |
| | Titrettor Pack (1 ea) | A-0053 |
|
|
|
|
|
| |
|